new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Nov 25

CheXpert Plus: Augmenting a Large Chest X-ray Dataset with Text Radiology Reports, Patient Demographics and Additional Image Formats

Since the release of the original CheXpert paper five years ago, CheXpert has become one of the most widely used and cited clinical AI datasets. The emergence of vision language models has sparked an increase in demands for sharing reports linked to CheXpert images, along with a growing interest among AI fairness researchers in obtaining demographic data. To address this, CheXpert Plus serves as a new collection of radiology data sources, made publicly available to enhance the scaling, performance, robustness, and fairness of models for all subsequent machine learning tasks in the field of radiology. CheXpert Plus is the largest text dataset publicly released in radiology, with a total of 36 million text tokens, including 13 million impression tokens. To the best of our knowledge, it represents the largest text de-identification effort in radiology, with almost 1 million PHI spans anonymized. It is only the second time that a large-scale English paired dataset has been released in radiology, thereby enabling, for the first time, cross-institution training at scale. All reports are paired with high-quality images in DICOM format, along with numerous image and patient metadata covering various clinical and socio-economic groups, as well as many pathology labels and RadGraph annotations. We hope this dataset will boost research for AI models that can further assist radiologists and help improve medical care. Data is available at the following URL: https://stanfordaimi.azurewebsites.net/datasets/5158c524-d3ab-4e02-96e9-6ee9efc110a1 Models are available at the following URL: https://github.com/Stanford-AIMI/chexpert-plus

  • 9 authors
·
May 29, 2024

CheXpert: A Large Chest Radiograph Dataset with Uncertainty Labels and Expert Comparison

Large, labeled datasets have driven deep learning methods to achieve expert-level performance on a variety of medical imaging tasks. We present CheXpert, a large dataset that contains 224,316 chest radiographs of 65,240 patients. We design a labeler to automatically detect the presence of 14 observations in radiology reports, capturing uncertainties inherent in radiograph interpretation. We investigate different approaches to using the uncertainty labels for training convolutional neural networks that output the probability of these observations given the available frontal and lateral radiographs. On a validation set of 200 chest radiographic studies which were manually annotated by 3 board-certified radiologists, we find that different uncertainty approaches are useful for different pathologies. We then evaluate our best model on a test set composed of 500 chest radiographic studies annotated by a consensus of 5 board-certified radiologists, and compare the performance of our model to that of 3 additional radiologists in the detection of 5 selected pathologies. On Cardiomegaly, Edema, and Pleural Effusion, the model ROC and PR curves lie above all 3 radiologist operating points. We release the dataset to the public as a standard benchmark to evaluate performance of chest radiograph interpretation models. The dataset is freely available at https://stanfordmlgroup.github.io/competitions/chexpert .

  • 20 authors
·
Jan 21, 2019

What Matters for Cross-Modal Alignment

The Platonic Representation Hypothesis posits that models trained on different modalities converge toward a shared representation. Related work aligns frozen image and text encoders on natural images without paired data. We test zero-pair alignment on five datasets across four modalities: natural images, environmental audio, chest radiographs, and 3D computed tomography (CT). It succeeds only on COCO and fails on the other four. We analyze the failures and find that alignment must first locate the subspace where the modalities co-vary and then orient the mapping within it. Consistent with previous studies, medical imaging is the hardest case: its shared subspace carries the smallest fraction of the variance. When this fraction is small, alignment needs image-text pairs, and random-matrix theory predicts how many pairs are needed. These findings motivate LightAlign: a few pairs let a ridge regression between two frozen encoders locate and orient the mapping simultaneously, and a classifier fitted only on report text then predicts findings from the mapped images. On 3D CT, LightAlign surpasses models trained end to end on image-report pairs without finding-level labels: with only 200 pairs, LightAlign outperforms CT-CLIP on CT-RATE (0.754 vs. 0.733 AUROC), and with only 100 CT-RATE pairs, it does so on RAD-ChestCT, an out-of-distribution dataset from a different hospital. On CheXpert, it reaches 0.862 mean AUROC with only about 5% as many pairs as models trained on MIMIC-CXR.

  • 7 authors
·
Nov 14

A Multi-Pass Large Language Model Framework for Precise and Efficient Radiology Report Error Detection

Background: The positive predictive value (PPV) of large language model (LLM)-based proofreading for radiology reports is limited due to the low error prevalence. Purpose: To assess whether a three-pass LLM framework enhances PPV and reduces operational costs compared with baseline approaches. Materials and Methods: A retrospective analysis was performed on 1,000 consecutive radiology reports (250 each: radiography, ultrasonography, CT, MRI) from the MIMIC-III database. Two external datasets (CheXpert and Open-i) were validation sets. Three LLM frameworks were tested: (1) single-prompt detector; (2) extractor plus detector; and (3) extractor, detector, and false-positive verifier. Precision was measured by PPV and absolute true positive rate (aTPR). Efficiency was calculated from model inference charges and reviewer remuneration. Statistical significance was tested using cluster bootstrap, exact McNemar tests, and Holm-Bonferroni correction. Results: Framework PPV increased from 0.063 (95% CI, 0.036-0.101, Framework 1) to 0.079 (0.049-0.118, Framework 2), and significantly to 0.159 (0.090-0.252, Framework 3; P<.001 vs. baselines). aTPR remained stable (0.012-0.014; P>=.84). Operational costs per 1,000 reports dropped to USD 5.58 (Framework 3) from USD 9.72 (Framework 1) and USD 6.85 (Framework 2), reflecting reductions of 42.6% and 18.5%, respectively. Human-reviewed reports decreased from 192 to 88. External validation supported Framework 3's superior PPV (CheXpert 0.133, Open-i 0.105) and stable aTPR (0.007). Conclusion: A three-pass LLM framework significantly enhanced PPV and reduced operational costs, maintaining detection performance, providing an effective strategy for AI-assisted radiology report quality assurance.

  • 6 authors
·
Jun 24, 2025

Pixel Perfect MegaMed: A Megapixel-Scale Vision-Language Foundation Model for Generating High Resolution Medical Images

Medical image synthesis presents unique challenges due to the inherent complexity and high-resolution details required in clinical contexts. Traditional generative architectures such as Generative Adversarial Networks (GANs) or Variational Auto Encoder (VAEs) have shown great promise for high-resolution image generation but struggle with preserving fine-grained details that are key for accurate diagnosis. To address this issue, we introduce Pixel Perfect MegaMed, the first vision-language foundation model to synthesize images at resolutions of 1024x1024. Our method deploys a multi-scale transformer architecture designed specifically for ultra-high resolution medical image generation, enabling the preservation of both global anatomical context and local image-level details. By leveraging vision-language alignment techniques tailored to medical terminology and imaging modalities, Pixel Perfect MegaMed bridges the gap between textual descriptions and visual representations at unprecedented resolution levels. We apply our model to the CheXpert dataset and demonstrate its ability to generate clinically faithful chest X-rays from text prompts. Beyond visual quality, these high-resolution synthetic images prove valuable for downstream tasks such as classification, showing measurable performance gains when used for data augmentation, particularly in low-data regimes. Our code is accessible through the project website - https://tehraninasab.github.io/pixelperfect-megamed.

  • 4 authors
·
Jul 16, 2025

Toward Clinically Acceptable Chest X-ray Report Generation: A Qualitative Retrospective Pilot Study of CXRMate-2

Chest X-ray (CXR) radiology report generation (RRG) models have shown rapid progress, yet their clinical utility remains uncertain due to limited evaluation by radiologists. We present CXRMate-2, a state-of-the-art CXR RRG model that integrates structured multimodal conditioning and reinforcement learning with a composite reward for semantic alignment with radiologist reports. Across the MIMIC-CXR, CheXpert Plus, and ReXgradient datasets, CXRMate-2 achieves statistically significant improvements over strong benchmarks, including gains of 11.2% and 24.4% in GREEN and RadGraph-XL, respectively, on MIMIC-CXR relative to MedGemma 1.5 (4B). To directly compare CXRMate-2 against radiologist reporting, we conduct a blinded, randomised qualitative retrospective evaluation. Three consultant radiologists compare generated and radiologist reports across 120 studies from the MIMIC-CXR test set. Generated reports were deemed acceptable (defined as preferred or rated equally to radiologist reports) in 45% of ratings, with no statistically significant difference in preference rates between radiologist reports and acceptable generated reports for seven of the eight analysed findings. Preference for radiologist reports was driven primarily by higher recall, while generated reports were often preferred for readability. Together, these results suggest a credible pathway to clinically acceptable CXR RRG. Improvements in recall, alongside better detection of subtle findings (e.g., pulmonary congestion), are likely sufficient to achieve non-inferiority to radiologist reporting. With these targeted advances, CXR RRG systems may be ready for prospective evaluation in assistive roles within radiologist-led workflows.

  • 10 authors
·
Apr 20